Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Korean Journal of Dental Materials ; (4): 153-164, 2019.
Article in Korean | WPRIM | ID: wpr-759677

ABSTRACT

In this study, marginal and internal discrepancies of zirconia crowns fabricated with the CAD/CAM (computer aided design


Subject(s)
Crowns , Methods , Molar , Replica Techniques , Shoulder , Silicon , Silicones , Tomography, X-Ray Computed , Tooth
2.
The Journal of Advanced Prosthodontics ; : 367-373, 2018.
Article in English | WPRIM | ID: wpr-742055

ABSTRACT

PURPOSE: To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS: A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the “Best-fit alignment” method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (α=.05). Tukey's HSD was used for post-hoc analysis. RESULTS: One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P < .001) and between areas (P < .001) were further revealed by 2-way ANOVA. CONCLUSION: Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range ( < 120 µm).


Subject(s)
Crowns , Methods
3.
The Journal of Korean Academy of Prosthodontics ; : 210-217, 2016.
Article in Korean | WPRIM | ID: wpr-195080

ABSTRACT

PURPOSE: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. MATERIALS AND METHODS: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (α=.05). RESULTS: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). CONCLUSION: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.


Subject(s)
Computer-Aided Design , Crowns , Follow-Up Studies , Mouth , Pilot Projects , Prospective Studies , Replica Techniques
SELECTION OF CITATIONS
SEARCH DETAIL